LPS=LPS_0, ET1D=ET1D_0, SPO=SPO_0, LPTA=LPTA_0, SRTCR=SRTCR_0, ESVD=ESVD_0, EO=EO_0, LPNS=LPNS_0, MCR=MCR_0, SED=SED_0
SNVS_LP Status Register
LPTA | LP Time Alarm 0 (LPTA_0): No time alarm interrupt occurred. 1 (LPTA_1): A time alarm interrupt occurred. |
SRTCR | Secure Real Time Counter Rollover 0 (SRTCR_0): SRTC has not reached its maximum value. 1 (SRTCR_1): SRTC has reached its maximum value. |
MCR | Monotonic Counter Rollover 0 (MCR_0): MC has not reached its maximum value. 1 (MCR_1): MC has reached its maximum value. |
PGD | Power Supply Glitch Detected 0 No power supply glitch. 1 Power supply glitch is detected. |
ET1D | External Tampering 1 Detected 0 (ET1D_0): External tampering 1 not detected. 1 (ET1D_1): External tampering 1 detected. |
ESVD | External Security Violation Detected Indicates that a security violation is detected on one of the HP security violation ports 0 (ESVD_0): No external security violation. 1 (ESVD_1): External security violation is detected. |
EO | Emergency Off This bit is set when a power off is requested. 0 (EO_0): Emergency off was not detected. 1 (EO_1): Emergency off was detected. |
SPO | Set Power Off The SPO bit is set when the power button is pressed longer than the configured debounce time 0 (SPO_0): Set Power Off was not detected. 1 (SPO_1): Set Power Off was detected. |
SED | Scan Exit Detected 0 (SED_0): Scan exit was not detected. 1 (SED_1): Scan exit was detected. |
LPNS | LP Section is Non-Secured Indicates that LP section was provisioned/programmed in the non-secure state 0 (LPNS_0): LP section was not programmed in the non-secure state. 1 (LPNS_1): LP section was programmed in the non-secure state. |
LPS | LP Section is Secured Indicates that the LP section is provisioned/programmed in the secure or trusted state 0 (LPS_0): LP section was not programmed in secure or trusted state. 1 (LPS_1): LP section was programmed in secure or trusted state. |